LU series low frequency solar inverter with power from 3KW to 12KW, split phase output voltge, 110V/220VAC, 120V/240VAC . The inverter can do with or without built in MPPT controller, also can connect with external PWM/MPPT controller to have more solar power input. Big toroidal transformer. strong load ability to support loads, such as AC, Pump, etc. inductive loads. Three working mode: Mains priority mode, Battery(solar) priority mode, Energy saving mode. It works with different type batteries, like lead acid battery, gel battery, deep cycle battery, LifePo4 lithium battery, etc.
Feature
◆ Equipped with split phase input/output function;
◇ Support split phase/single-phase input setting function;
◆ New exterior design with built-in photovoltaic MPPT controller;
◇ Low loss power frequency transformer, high inverter efficiency, pure sine wave output;
◆ Intelligent LCD integrated display;
◇ The charging current of the mains power can be set, making the user's battery capacity configuration more flexible;
◆ It has the function of setting working modes;
◇ Equipped with lithium battery BMS communication function;
◆ Equipped with fully automatic and comprehensive protection functions;
◇ Support diesel (gasoline) generators, suitable for working in harsh electrical environments;
◆ Wall mounted installation design, easy to install.
Specification
Specification |
Model: LU/LUT |
30248 |
50248 |
60248 |
80248 |
10348 |
12348 |
Rated Power |
3KW |
5KW |
6KW |
8KW |
10KW |
12KW |
Peak Power(20ms) |
9KVA |
15KVA |
18KVA |
24KVA |
30KVA |
36KVA |
Start Motor |
3HP |
4HP |
4HP |
6HP |
8HP |
8HP |
Battery Voltage |
48VDC |
Max AC charging current |
15A |
25A |
30A |
35A |
50A |
50A |
Size(L*W*Hmm) |
470*300*140 |
530*335*150 |
684*450*240.5 |
Packing Size(L*W*Hmm) |
545*385*223 |
605*420*238 |
705*485*315 |
N.W.(kg) |
|
|
|
|
|
|
G.W.(kg) |
|
|
|
|
|
|
Installation Method |
Wall-Mounted |
Parameter |
Input |
DC Input Voltage Range |
42-60VDC |
AC Input Voltage |
220VAC/240AC (Split phase L1-N-L2) or
110V/120AC (Single-phase L1-N) |
AC Input Voltage Range |
Split phase: 170VAC~275VAC (220VAC)/190VAC~295VAC (240VAC) or
Single-phase: 85VAC~138VAC (110VAC)/95VAC~148VAC (120VAC) |
AC Input Frequency Range |
45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz) |
AC charging method |
Three-stage (constant current, constant voltage, floating charge) |
Output |
Efficiency(Battery Mode) |
≥85% |
Output Voltage(Battery Mode) |
L1-N/L2-N:110VAC or 120VAC ; L1-L2: 220VAC or 240AC |
Output Frequency(Battery Mode) |
50/60Hz±1% |
Output Wave(Battery Mode) |
Pure Sine Wave |
Efficiency(AC Mode) |
>99% |
Output Voltage(AC Mode) |
L1-N/L2-N:110VAC or 120VAC ; L1-L2: 220VAC or 240AC |
Output Frequency(AC Mode) |
Follow input |
Output waveform distortion
(Battery Mode) |
≤3% (Linear load) |
No load loss(Battery Mode) |
≤0.8% rated power |
No load loss(AC Mode) |
≤2% rated power(charger does not work in AC mode) |
Battery Type
(selectable) |
VRLA Battery |
Charge Voltage :56.8V; Float Voltage:55.2V |
Customize battery |
Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel) |
Protection |
Battery undervoltage alarm |
Factory default: 44V |
Battery undervoltage protection |
Factory default: 42V |
Battery overvoltage alarm |
Factory default: 60V |
Battery overvoltage protection |
Factory default: 64V |
Battery overvoltage recovery voltage |
Factory default: 58V |
Overload power protection |
Automatic protection (battery mode),
circuit breaker or insurance (AC mode) |
Inverter output short circuit protection |
Automatic protection (battery mode),
circuit breaker or insurance (AC mode) |
Temperature protection |
>90°C(Shut down output) |
Inside Solar controller
(Optional) |
Charging Mode |
MPPT |
Charging Current |
60A |
100A |
200A |
PV Input Voltage Range |
60V-140Vdc |
60V-240Vdc |
Max PV Input Voltage(Voc)
(At the lowest temperature) |
180V |
300V |
PV Array Maximum Power |
3360W |
5600W |
11.2KW |
|
MPPT Tracking Channels/Input Channels |
1/1 Routed |
1/2 Routed |
Working Mode |
Battery First/AC First/Saving Energy Mode(can be set) |
Transfer Time |
≤4ms |
Display |
LCD |
Thermal method |
Cooling fan in intelligent control |
Communication(Optional) |
RS485/APP(WIFI monitoring or GPRS monitoring) |
Environment |
Operating temperature |
≤55dB |
Storage temperature |
-10℃~40℃ |
Noise |
-15℃~60℃ |
Elevation |
2000m(More than derating) |
Humidity |
0%~95% ,No condensation |
Why choose us
Automated production
It has advanced automated production lines and is equipped with high-precision equipment
R&D & Testing
Our professional R&D team is committed to technological innovation
Assembly Line
Different assembly line for different type inverters
Aging and final testing
Each products will be aging and final testing to make sure the quality before shipment
Testing & Packaging
Each inverter undergoes multiple quality inspections before leaving the factory
Delivery
Our goods are sent to different countries of the world, welcome all the customers to inquire of our products
Factory Show